overview
photo gallery
calculator
distributors
FAQ
Buy Now
pedestal options
holddown options
ventilation
effluent discharge options
buildings
cleaning
system management
maintenance
owners manual
retrofits
retrofits
ws13
gough plastics home
 

315mm Polyethylene Vent Column

This option is only suitable for certain circumstances.

Normally used in highly treed low wind areas where other options will not work.  

Features:

  • No moving parts.
  • Nil Power requirement.

How Does It Work

Air movement across the open top of the vent tube creates a negative pressure drawing air up the tube. Also sunlight on the tube heats the plastic causing the air inside to heat up causing the air to rise in the tube.  

Drawbacks

The tube is very large and visually very obvious. We recommend the top of the vent tube to be a minimum of a meter above the roof line to work most effectively. Consideration also needs to be given to the design of the structure to make the vent work most effectively. Vents installed with the top outlet too low may not work at all and actually create a downward flow.