overview
photo gallery
calculator
distributors
FAQ
Buy Now
pedestal options
holddown options
ventilation
effluent discharge options
buildings
cleaning
system management
maintenance
owners manual
retrofits
retrofits
ws13
gough plastics home
 

MicroFlush

Assembly and Installation Instructions

Drawings

Pedestal Assembly GTL-0000-17
Pedestal Installation GTL-0000-18

The following instructions should be read in conjunction with Drawings GTL-0000-17 and GTL-0000-18 and the related Hybrid drawing.

  1. As per Drawing GTL-0000-18, the minimum set out distance from the wall to the centre of the dropper tube is 300mm. If you wish to install the pedestal further out from the wall, determine the required spacing from the wall and add to dimension ‘A’. Consideration needs to be given to the under-floor structure when determining the position of the dropper tube.
  2. Draw a line, square out from the wall behind the toilet, approximately 650mm long through the centre line of the pedestal.
  3. Measure out and mark the position of the dropper tube on this line at the required distance out from the wall. Locate the 150mm dropper tube marked ‘E’ on Drawing GTL-0000-17.
  4. Slide the piece of 150mm pipe down through the floor until it rests on the lid of the tank. Using a spirit level, plumb the piece of pipe. It is important that this pipe is vertical. Mark the hole to be cut in the tank lid by scribing around the pipe onto the lid of the tank with a marking pen or similar.
  5. As before, cut the hole in the tank lid with the jigsaw.
  6. Using a measuring tape, measure from the floor down to the lowest point on the tank lid. Add 50mm to this dimension. Measure from the end of the pipe with the screw in it and cut off the excess.
  7. To install the moulded black transition piece marked ‘C’, using silicone, run a bead around the spigot end of the transition, about 20mm in from the end. Note the position of the pre-drilled hole.
  8. Remove the screw from the dropper tube and slide the transition spigot into the dropper tube. Install the screw into the pre-drilled hole in both tube and transition.
  9. Place the pedestal marked ‘D’ on the floor over the dropper hole. Slide the assembled dropper tube down through the pedestal and the floor and into the hole in the tank.
  10. Place the top plate bowl assembly marked ‘B’ into the top of the pedestal and gently manoeuvre into position. You will need to push the flap down with your hand as you engage the transition. Using the centre line as a guide, position the pedestal ensuring that the stainless steel flap hinges fully down and returns without interference.
  11. Mark around the perimeter of the pedestal onto the floor and remove the internal components and remove the pedestal. In the marked area of the rear section of the pedestal, drill or holesaw a 25mm hole in the floor to take the black water hose. Note, stay inside the line of the flange.
  12. Note the pre-drilled holes in the internal flange of the pedestal base. Seal under the flange with silicone if appropriate by placing a bead of silicone on the floor and fix the pedestal through these holes with the screws provided.
  13. If these holes are unsuitable, select new positions and pre-drill the holes so as not to damage the fibreglass flange.
  14. Re-install the dropper tube assembly. Next, feed the black hose through the 25mm hole in the floor and install the top plate. Fit the seat marked ‘A’ to the top plate and tighten the seat bolts.
  15. Check that the stainless steel flap moves freely without catching.
  16. Using silicone, seal around the dropper tube penetration through the floor from the under side and the penetration into the tank lid.
  17. The MicroFlush assembly should now be ready to connect to the flushing mechanism. Refer to the appropriate flushing mechanism installation instructions for next step.

THANK YOU FOR CHOOSING ‘THE HYBRID TOILET SYSTEM’.

Should you have any problems with installation of this system, please do not hesitate to contact: your local agent on 1800 069 805.